LED display products · Huizhou, China
Blog / LED Display Guide

How to Choose an Outdoor LED Display Supplier for Your Project

Practical LED display buying advice for overseas project buyers, event teams, integrators and commercial screen owners.

Illustration of a buyer reviewing an outdoor LED billboard drawing
Illustrative planning scene. Use the supplier’s dimensioned drawing to verify the offered cabinet configuration.

What should all outdoor LED display suppliers quote against?

Send the target active width and height, the hard limits of the opening, the closest and typical viewpoints, site photos, sun exposure, operating hours and the delivery location. Explain whether the screen shows advertising, small text or live video. Ask each bidder to return a named model, cabinet count and finished drawing.

State whether the job is a permanent billboard, a façade display, a stadium screen or a temporary event wall. Mark which side is available for service and where power and signal can enter. Put these details in the same brief for every bidder so model changes and exclusions remain easy to compare.

How do you check the supplier’s cabinet grid and power assumptions?

Divide each target dimension by the corresponding cabinet dimension and round up to whole columns and rows when the target is a minimum. Calculate the resulting face size and cabinet count from that grid. Compare the finished size against the opening before using the catalog power density to estimate wall load.

2026 Mirun catalog models FC6.67 (p. 13) and FS2.604 (p. 15), with calculated results for an upright flat wall targeting at least 5.6 × 2.75 m.
CheckFC6.67FS2.604
Nominal pitch and cabinet face6.67 mm · 960 × 960 mm2.604 mm · 500 × 1,000 mm
Catalog brightness and IP rating≥5,500 cd/m² · IP66≥5,000 cd/m² · IP66
Cabinet grid and actual face6 × 3 = 18 · 5.76 × 2.88 m12 × 3 = 36 · 6 × 3 m
Approximate cabinet-only mass450 kg at 25 kg each576 kg at 16 kg each
Catalog maximum and average power density550 / 186 W/m²550 / 186 W/m²
Estimated wall maximum and average power9.12 / 3.09 kW9.90 / 3.35 kW

Wall power multiplies the actual face area by the listed density and divides watts by 1,000. The figures cover the cabinets. The structure, accessories and site electrical allowances require a separate review. If 5.6 × 2.75 m is a hard limit, both illustrated layouts exceed it. Review the FC and FS outdoor cabinet specifications and use the LED screen layout and power calculator to test another target.

Which weather and service details belong in writing?

Ask the supplier to identify the tested cabinet configuration and where the IP rating applies. Confirm connector protection, cable entry, drainage and service access with the installer after cladding is in place. For bright sites, agree on test conditions for daytime legibility, the night brightness setting and the proposed dimming controls.

Illustrated procurement checklist with LED cabinets, a brightness meter and packing equipment
Illustrative equipment checklist. Request test records and packing evidence tied to your order.

Ask for drawings that show how the team will remove modules, power supplies and receiving cards. Identify who specifies the support and wind-load requirements, who designs electrical protection, and who approves the installed work. For shipment, request the agreed test record, cabinet labels, packing list, gross weights, spare quantities and control configuration files.

Compare scope with the LED display quotation guide. Then request an itemized outdoor LED display quotation with the drawing, delivery point and local installation responsibilities.

Outdoor LED display supplier FAQ

What should I ask a supplier to prove before paying a deposit?

Request the proposed model, dimensioned cabinet layout, quoted bill of materials, agreed proof of the model’s weather protection and a written inspection plan. Record who supplies installation drawings and what the buyer must arrange locally.

Is IP66 enough to specify the complete outdoor display?

Ask which cabinet faces and components the supplied rating covers. Agree on the installed connector and cable-entry details, exposure direction, drainage and clearance before approving the finished assembly.

How should buyers compare brightness across two supplier quotes?

Ask each supplier for the model-specific figure and the conditions under which it is measured. Compare both bids against the actual site exposure, content and night operation. Include the agreed acceptance test in the order.

What should I check when one outdoor quote is much cheaper?

Reconcile the cabinet count, controls, compatible spares, packaging, delivery scope and local installation responsibilities line by line. Ask both bidders to mark exclusions and state which inspection results and files accompany the shipment.

Need help choosing the right LED display?

Tell us your installation scene, screen size, pixel pitch target and timeline. Mirun Hailian can help match the right product configuration.

Discuss your project

Open the inquiry form
WA