H and K Series Rental LED Cabinets
Compare H and K rental cabinet systems, dimensions, service access and specifications before choosing a project configuration.
Selection at a glance
- Pixel pitch
- 1.95 mm; 2.604 mm; 2.976 mm; 3.91 mm; 4.81 mm
- Brightness
- The catalog lists indoor brightness ≤800 cd/m² and outdoor brightness ≤4500 cd/m². These are printed upper limits.
- Cabinet size
- 500 × 500 mm; 500 × 1000 mm
- Cabinet weight
- 500 × 500 mm – 7 kg; 500 × 1000 mm – 12.5 kg
- Refresh rate
- 3840 / 7680 Hz
- IP rating
- The tables list IP65; confirm the protected surfaces, connectors and installed configuration before outdoor use.
- Application
- Indoor and outdoor rental
How do H and K Series cabinets differ?
Use the project hardware to decide between H and K once the pitch and screen dimensions are set. H Series catalog examples show curved and right-angle backdrop assembly. K Series catalog details show a damping handle, stainless steel quick locks and lower impact-absorbing protrusions. Ask which parts ship with the chosen cabinet.

Request joint and lock drawings for the quoted model. For a curved layout, ask for the allowed angle range and connection hardware for that cabinet. If a project already stocks modules, receiver cards or interconnects, match the existing parts to the offered model number.
Which H/K pixel pitch fits a stage backdrop?
Start with the smallest text the audience must read and the closest planned viewing position. For a 4 × 3 m wall using 48 small cabinets, the catalog P1.95 matrix gives 2,048 × 1,536 pixels and P2.604 gives 1,536 × 1,152 pixels. Check the smallest label and camera framing on the proposed processor map.
| Catalog model label | Pixel pitch (mm) | Catalog cabinet resolution (pixels) | Scan mode | Refresh options (Hz) |
|---|---|---|---|---|
| P1.95 (small cabinet) | 1.95 | 256 × 256 | 1/32 | 3840 / 7680 |
| P2.604 (small cabinet) | 2.604 | 192 × 192 | 1/24 | 3840 / 7680 |
| P2.976 | 2.976 | 168 × 168 | 1/21 | 3840 / 7680 |
| P3.91 | 3.91 | 256 × 128 | 1/16 | 3840 / 7680 |
| P4.81 | 4.81 | 208 × 104 | 1/13 | 3840 / 7680 |
The calculated small-cabinet canvases are both 4:3. For a 16:9 feed, agree how the content will fit the wall. Ask for the cabinet orientation, native canvas and refresh setting included in the quotation. The catalog tables give no model-specific minimum viewing distances.
Should I choose 500 × 500 mm or 500 × 1000 mm cabinets?
Choose the 500 × 500 mm format when the 7 kg cabinet weight and finer layout increments suit the crew. Choose 500 × 1000 mm when fewer 12.5 kg panels suit the agreed layout and handling plan. For a 4 × 3 m face, the two full-cabinet layouts weigh 336 kg and 300 kg.
| Cabinet format | Face area (m²) | Cabinet weight (kg) | Cabinet grid and count | Cabinet-only weight (kg) |
|---|---|---|---|---|
| 500 × 500 mm | 0.25 | 7 | 8 columns × 6 rows = 48 | 336 |
| 500 × 1000 mm | 0.50 | 12.5 | 8 columns × 3 rows = 24 | 300 |
The large-cabinet example assumes a 500 mm wide and 1000 mm tall installation orientation. Both examples exclude rigging, structure, cables and cases. Confirm availability for the chosen pitch, orientation and layout before relying on either count. For a 7.5 kg square alternative, compare the R Series RS and RX 500 × 500 mm cabinets.
What power and brightness should I budget for an H/K wall?
Use the H/K catalog maximum of ≤800 W/m² to estimate the screen load ceiling. A 4 × 3 m active face is 12 m², so its catalog-based ceiling is 9.6 kW for the display alone. Request the quoted cabinet’s maximum and expected operating power, measured brightness, and test conditions before finalizing the supply.
Both tables list die-cast aluminum construction, maximum power consumption ≤800 W/m², 3840/7680 Hz refresh options and adjustable 14–16 bit grayscale. The catalog tables give no average-power figure. Separate the controller and other equipment loads for the electrical review.
The catalog lists indoor brightness ≤800 cd/m² and outdoor brightness ≤4500 cd/m². These are printed upper limits. Ask for measured brightness and acceptance criteria for the actual cabinet. The tables list IP65; confirm the protected surfaces, connectors and installed configuration before outdoor use.
Use the LED display quotation scope checklist to agree on controls, power, connection hardware and accessories. Send the active dimensions, venue conditions, sample content and camera settings to request an H/K cabinet and canvas quotation.
Specification source: LED Display Catalog 2026, H Series pages 6–8 and K Series pages 9–11. The layouts are design examples. Confirm all figures for the supplied configuration.
H and K Series purchasing FAQ
Can I build the same wall out of both cabinet sizes?
Ask the supplier for a mixed-format drawing showing the part numbers, pitch, cabinet orientation, locking positions and receiving-card map. Confirm the proposed cabinet combination with a sample assembly before ordering parts for the full wall.
Will the quoted H or K cabinets run on 110 V or 220 V at our venue?
Request the exact power-supply input range, frequency and connector details, then ask for the cabinet grouping and feed drawing for the venue. Have the local electrical professional check it against the actual distribution.
Can I use my existing NovaStar controllers and keep the quoted refresh option?
Send the controller model and firmware with your proposed layout. Ask for the receiving-card model, cabinet configuration files and the refresh setting included in the quote. Confirm the combination in playback and camera tests.
How many large cabinets fit in one flight case, and how should I pack spares?
Request a packing plan showing cabinets per case, packed dimensions and gross weights for the chosen format. List spare modules, receiving cards, power supplies and locks separately, with exact part numbers and agreed spare quantities.
Can I service the modules and power supplies from the front?
Ask for the quoted cabinet’s service drawing. Confirm the removal direction and tool clearance for modules, receiving cards and power supplies. Review access after the rigging, frame and stage masking are in place.